Elrec 10 Specifications @ Fugro Instruments


Iris Instruments offer a comprehensive range of geophysical instruments, environmental monitoring equipment and geotechnical instruments. Information about IRIS Induced Polarization and Proton Magnetic Resonance systems may be viewed by following the links. For a complete listing of Iris Instruments products, click on the rotating Ohm symbol to visit the IRIS web site.


Elrec 6 Induced Polarisation Receiver
Technical specifications
- Ten input dipoles
- Signal waveform: Time Domain (ON+, OFF, ON

-, OFF) with pulse duration of 0.5 , 1 , 2 , 4 or 8 seconds
- Up to twenty arithmetic, logarithmic or fully programmable IP chargeability windows
- Computation of apparent resistivity, average chargeability and standard deviation
- Input impedance: >50 Mohms
- Input overvoltage protection up to 1000 Volts
- Automatic SP bucking ±15V with linear drift connection
- Internal calibration generator for a true calibration on request of the operator
- Automatic synchronization and re-synchronization process on primary voltage signals whenever needed
- Automatic stacking number in relation with a given standard deviation value
- Proprietary intelligent stacking process rejecting strong non-linear SP drifts
- Common mode rejection: more than 100 dB (for Rs = 0)
- Ground resistance measurement from 0.1 to 100 kohms
- Battery test: graphic plot of battery status
- Primary voltage: range: 10 µV to 15V, resolution: 1µV, accuracy: typ. 0.3%
- Chargeability: range: 10µV to 15V, accuracy: typ. 0.6%
- Self Potential: range: ±15V, resolution: 0.1 mV
- Time constant (tau) range: Cole-Cole inversion continuous from 10 milliseconds to 100 seconds ; Customized range on request

- Dimensions: 31x21x25 cm
- Display: 16 lines by 40 characters, 128 x 240 dots LCD, with automatic compensation of contrast and of temperature
- Keypad: 16 keys
- Weight: 8 kg including internal battery
- Operating temperature: -30°C to +70°C
- Power supply: 12V internal rechargeable battery with more than 20 hours service at +20°C ; a 12V external battery can be also used.
 ELREC 10, Ten dipole IP receiver

The With graphics display for data quality monitoring

TEN SIMULTANEOUS DIPOLES
TWENTY PROGRAMMABLE CHARGEABILITY WINDOWS
HIGH ACCURACY AND SENSITIVITY

ELREC 10 is a ten dipole Time Domain Induced Polarization receiver designed for high productivity surveys in Mineral Exploration. ELREC 10 is a highly sensitive receiver and features a large graphic display for user friendly operation and a Cole-Cole parameter computation for in-the-field time constant analysis.

Ten dipoles:
The ten dipoles of ELREC 10 offer an increased productivity in the field for dipole-dipole, gradient or extended poly-pole arrays. It is also possible to measure five differential (non adjacent) dipoles, for special electrode configurations.

Twenty programmable windows:
Beside classical arithmetic and logarithmic modes, ELREC 10 also offers twenty fully programmable windows for a higher flexibility in the definition of the IP decay curve.

User Friendly Interface:
user friendly interface has been set up in ELREC 10 with a minimal number of key strokes for each operation.

Intelligent Stacking Process:
When the electric noise has strong non-linear effects, the standard arithmetic stacking process requires a long acquisition time to measure the IP effect ; a proprietary intelligent stacking algorithm has been specially developed in ELREC 10 to deal with strong non-linear SP bursts and minimize the acquisition time for a given reading accuracy

Monitoring Display:
A large graphic LCD (128x240 dots) permits the operator to display simultaneously the IP decay curves of the ten dipoles during the acquisition, for a global visualization of the readings and for better quality control. Before the acquisition, the ELREC 10 can be used as a one channel DC graphic display, for monitoring the noise level and checking the primary voltage waveform, through a continuous display process.

Cole-Cole Parameters:
An inversion procedure has been implemented to compute Cole-Cole time constant at the end of the acquisition. This allows a possible grain size discrimination analysis.

Internal Memory:
The memory can store up to 3200 dipole readings, each reading including the full set of parameters characterizing the measurements. An explicit data storage procedure has been developed including the display of warning messages for data not yet stored. File names are available for a better memory management of sets of readings.

Field proof Instrument:
ELREC 10 operates in a wide temperature range and features a fiber-glass case for resistance to field shocks and vibrations.



Copyright © 1998 IRIS Instruments

 