The following data was acquired at the Xiao Tang Shan Hot Spring Area, North Beijing, China.
The Xiao Tang Shan area of China is known to have geothermal activity concentrated along fault lines,
and a Stratagem survey was peformed to verify the location of a known fault exhibiting the geothermal type activity.
The survey consisted of forty (40) stations using 15 metre dipole spacings for a total survey line
length of 600 metres. The data was then processed using Stratagem's 1D and 2D inversion software.
The resulting X, Y, Z file created by Stratagem's EMAP 2D processing
was contoured using Geosoft mapping software and output to a colour printer.
|